3/8” Super Flexible RF Coaxial Cable
|
 |
| Type Type No. |
Standard cable HCAHY-50-7
Fire-retardant cable HCAHYZ-50-7 |
| Construction |
Inner
conductor |
Material |
CCA |
| Diameter(mm) |
2.60±0.05 |
| Insulation |
Material |
Foamed PE |
| Diameter(mm) |
7.0±0.2 |
Outer
conductor |
Material |
Helical corrugated copper tube |
| Diameter(mm) |
9.0±0.2 |
| Jacket |
Material |
LLDPE or fire-retardant PE |
| Min.thickness(mm) |
>0.4 |
| Diameter(mm) |
10.4±0.2 |
| Mechnical Characteristics |
| Bending radius(mm) |
Single bend |
15 |
| Repeated bend |
50 |
| Tensile strength(N) |
600 |
| Cable weight(kg/km) |
110 |
| Recommended temperature(℃) |
Storage |
-70~+85 |
| Installation |
-40~+60 |
| Operating |
-55~+85 |
|
| Products meet the RoHS requirement, and according to the requirements of RoHS, you can see the RoHS mark on the outside package. |
|
| Electrical Characteristics |
| Inner conductor DC resistance(Ω/km) |
5.30 |
| Outer conductor DC resistance(Ω/km) |
4.50 |
| Characteristic impedance(Ω) |
50±1 |
| Capacitance(p F/m) |
82 |
| Velocity(%) |
81 |
| Dielectric strength(KV) |
2.5 |
| Insulation resistance(MΩ/km) |
>1×104 |
| Peak power rating(KV) |
13.4 |
| Peak voltage(V) |
1200 |
| Cut-off frequency(GHz) |
17.0 |
| Attenuation and Average power |
Frequency
(MHz) |
Attenuation
(@20℃,d B/100m) |
Average power(kv) |
| 150 |
4.94 |
1.54 |
| 450 |
8.57 |
0.87 |
| 800 |
11.91 |
0.64 |
| 900 |
12.79 |
0.60 |
| 1000 |
13.64 |
0.57 |
| 1500 |
17.60 |
0.45 |
| 1800 |
19.84 |
0.41 |
| 2000 |
21.27 |
0.39 |
| 2200 |
22.68 |
0.37 |
| 2500 |
24.76 |
0.34 |
| 3000 |
28.10 |
0.31 |
| VSWR |
| 800MHz~1000MHz |
1.10 |
| 1700MHz~2000MHz |
1.13 |
| 2100MHz~2400MHz |
1.15 |
|
Note:
For fire-retardant jackter cable,recommended temperature:
Storage:-30℃~+80℃
Installation:-25℃~+60℃
Operating temperature:-30℃~+80℃ |
|